Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application

Product Details
Customization: Available
After-sales Service: 24-Hour After-Sales Online
Warranty: 12 Monthes
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
15000000 RMB
Plant Area
>2000 square meters
  • Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
  • Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
  • Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
  • Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
  • Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
  • Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
Find Similar Products

Basic Info.

Model NO.
KAC400 KAC800 M10BW
Certification
CE, ISO
Application
Heater, Cooler, Vaporizer, Condenser
Principle
Mixing Heat Exchanger
Style
Plate Type
Material
Stainless Steel
Plate Material
316/316L, Ti
Customized
Customized
Frame Material
Carbon Steel, Stainless Steel etc.
Connection Material
Rubber Gasket, Stainless Steel, etc
Gasket Material
NBR, EPDM, HNBR, Viton, FKM
Suitable Fluid
Water, Sea Water, Oil, Brine, Acid, Soda
Delivery Time
7 -10working Days
Operating Temperature
-25 ~ +200 C
Transport Package
Plywood Case
Specification
Semi-welded
Trademark
King DuPont
Origin
Jiangsu, China
HS Code
841950090
Production Capacity
3000-5000pieces/Year

Product Description

Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
The Plate heat exchanger consists of a pack of corrugated metal plates, The corrugation of the plates provides the passage between the plates, the two fluids transfer the heat between the channels. The plate pack is assembled between a fixed frame plate and a movable pressure plate and compressed by tightening bolts. The gasket between the plates seals the interplate channel and directs the fluids into alternate channels. The number of plates is determined by the design: the temperature program, flow rate, pressure drop and physical properties of the fluids.


Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application

Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
 



Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application

High heat transfer efficiency : Plate heat exchanger has a very high heat transfer coefficient, usually between4000-12000W/m2C. Since the medium flowing in the plate group can form a strongturbulence at a low Reynolds number (Re).

Low scaling rate : Dirty scale is difficult to deposit. Because the fluid turbulent inside the plate and theflow rateevenly spreads the entire plate, the surface of the plate is relatively smooth.

Great flexibility : The plate heat exchangers can be combined optimally and adapt changes in thermaload flexibly, since the plates can be combined into various processes. You only needto increase or decrease the number of plates, and it can adapt to the new changeswithout having to change the frame.

Low retention : The plate heat exchanger can be very good at controlling the temperature of thesecondary side medium, since the flow path and volume is small, and the amount offluid residing inside the heat exchanger is small. Especially in the treatment of heatsensitive materials,plate heat exchangers are better.

Compact structure : Under the same heat transfer conditions, the plate heat exchanger covers only about1/3 area of the shell-and-tube heat exchanger for saving a precious space. Besidesthere is no need to take up extra space when disassembling and repairing.

Easy maintenance : The plate is designed with no dead space, so it can be chemically cleaned on sitewithout disassembly. Even though it needs disassembly, a worker usually cancomplete the replacement cleaning.



Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
 
Industrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator ApplicationIndustrial Semi-Welded Gasketed Plate Heat Exchanger for Flooded Nh3 Evaporator Application
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier